Restoring the factory default settings on the MIP unit |
|
How do I set the mIP to default factory settings?
|
|
Product:
MIP |
FAQ Type:
Configuration |
Answer:
With the mI powered off, place a piece of metal between the pins at jumper P2. Power on the mIP and during the second round of flashings LEDs, remove the metal piece and a third round of flashing LEDs should follow. That indicates that the process was successful. It there was not a third round of LEDs flashing, the process failed and should be reattempted.
|
|